SMART 3-R

The SMART 3-R and 3-R Lite refrigerant gas detectors have options for the detection of more than ten refrigerant gases, with the SMART 3-R also capable of detecting over ten flammable and toxic gases. The devices are designed for use in machinery/plant rooms and laboratory settings and feature both audible and visual indications of detector status.

Compare

Overview

The SMART 3-R and 3-R Lite are refrigerant gas detectors designed for use in non-classified areas, machinery/plant rooms and laboratories.

Audible and visual status notifications

The multi-colour LED light ring offers a constant visual indication of detector status whilst an internal buzzer will activate to warn of any fault or alarm condition.

Wide variety of gas and sensor options

Both the SMART 3-R and 3-R Lite have options for the detection of more than ten refrigerant gases, with the SMART 3-R also capable of detecting over ten flammable and toxic gases.

Refrigeration Standards compliance

The devices are compliant with the refrigeration standards EN 378-3; EN 14624; EN 50676; IEC 60335-2-40 Annex LL and ISO 5149-3

Specification

SMART3-R SMART3-R Lite
Size Box: H120 x W120 x D52 mm (4.72 x 4.72 x 2.1ins)
Cover: H130 x W130 x D22 mm (5.12 x 5.12 x 0.87ins)
Remote head box: H106 x W106 x D56 mm (4.17 x 4.17 x 2.2ins)
Box: H120 x W120 x D52 mm (4.72 x 4.72 x 2.1ins)
Cover: H130 x W130 x D22 mm (5.12 x 5.12 x 0.87ins)
Weight Detector: 0.45kg
Remote head: 0.3kg
0.45kg
Enclosure material Polycarbonate
Ingress Protection IP42 IP54
Connection 2 entries with M20 cable glands
6 optional entries for M16 cable glands
Power 12-24 Vdc or 90-240Vac (SMART3-R only)
Electrical output 3 relays; RS485 serial output, 4-20 mA analogue output (only for 12-24 Vdc version) 2 relays; RS485 serial output (optional)
Operating temperature -40 / +60°C (catalytic sensor)
-40 / +50°C 230V version (catalytic sensor)
-40 / +60°C (infrared sensor, -10 / +50°C  ppm refrigerant gases)
-40 / +50°C 230V version (infrared sensor, -10 / +50°C for ppm refrigerant gases)
-30 / +50°C (electrochemical sensor)
-10 / +50°C
Humidity 0 / 95% RH non condensing (catalytic and infrared sensor)
15 / 90% RH non condensing (electrochemical sensor)
0 / 95% RH non condensing
Compliance EMC EN 61000-6-3:2007 + A1:201; EN 50270:2015
Electrical safety (90-240 Vac version) EN 61010-1: 2010 / A1: 2019
Refrigeration Standards EN 378-3; EN 14624; EN 50676; IEC 60335-2-40 Annex LL; ISO 5149-3; F-Gas Regulation

Refrigerants

Sensor type Device
R1233ZD Infrared sensor SMART3-R Only
R1234YF Infrared sensor SMART3-R and SMART3-R Lite
R1234ZE Infrared sensor SMART3-R and SMART3-R Lite
R125 Infrared sensor SMART3-R Only
R134A Infrared sensor SMART3-R and SMART3-R Lite
R152 Infrared sensor SMART3-R Only
R32 Infrared sensor SMART3-R and SMART3-R Lite
R404A Infrared sensor SMART3-R and SMART3-R Lite
R407A Infrared sensor SMART3-R Only
R407C Infrared sensor SMART3-R and SMART3-R Lite
R407F Infrared sensor SMART3-R Only
R410A Infrared sensor SMART3-R and SMART3-R Lite
R417A Infrared sensor SMART3-R Only
R448 Infrared sensor SMART3-R Only
R449A Infrared sensor SMART3-R Only
R452B Infrared sensor SMART3-R Lite Only
R454A Infrared sensor SMART3-R Lite Only
R454B Infrared sensor SMART3-R and SMART3-R Lite
R454C Infrared sensor SMART3-R Lite Only
R507A Infrared sensor SMART3-R Only
SF6 Infrared sensor SMART3-R Only

Gases

Sensor type Device
Ammonia (NH3) Electrochemical sensor SMART3-R Only
Butane (C₄H₁₀) Catalytic sensor / Infrared sensor SMART3-R Only
Carbon Dioxide (CO₂) Infrared sensor SMART3-R and SMART3-R Lite
Carbon Monoxide (CO) Electrochemical sensor SMART3-R Only
Hydrogen Sulphide (H2S) Electrochemical sensor SMART3-R Only
LPG Catalytic sensor SMART3-R Only
Methane (CH₄) Catalytic sensor / Infrared sensor SMART3-R Only
Nitrogen Dioxide (NO₂) Electrochemical sensor SMART3-R Only
Oxygen (O2) Electrochemical sensor SMART3-R Only
Petrol Vapours Catalytic sensor SMART3-R Only
Propane (C₃H₈) Catalytic sensor / Infrared sensor SMART3-R Only
Sulphur Dioxide (SO₂) Electrochemical sensor SMART3-R Only

 

Downloads

Datasheet