Water Treatment: The Need For Gas Detection In Detecting Chlorine

Water utility companies help provide clean water for drinking, bathing, and industrial and commercial uses. Wastewater treatment plants and sewage systems help keep our waterways clean and sanitary. Throughout the water industry, the risk of gas exposure and gas-associated hazards are considerable. Harmful gases can be found in water tanks, service reservoirs, pumping wells, treatment units, chemical storage and handling areas, sumps, sewers, overflows, boreholes, and manholes.

What Is Chlorine and Why Is It Dangerous

Chlorine (Cl2) gas appears yellow green in colour, used to sterilise drinking water. However, most chlorine is used in the chemical industry with typical applications including water treatment as well as within the plastics and cleaning agents. Chlorine gas can be recognised by its pungent, irritating odour, which is like the odour of bleach. The strong smell may provide adequate warning to people that they are exposed. Cl2 itself is not flammable, but it can react explosively or form flammable compounds with other chemicals such as turpentine and ammonia.

Chlorine gas can be recognised by its pungent, irritating odour, which is like the odour of bleach. The strong smell may provide adequate warning to people that they are exposed. Chlorine is toxic and if inhaled or drunk in concentrated quantities can prove fatal. If chlorine gas is released into the air, people may be exposed through their skin, eyes or through inhalation. Chlorine is not combustible however can react with most combustibles which poses a fire and explosion risk. It also reacts violently with organic compounds such as ammonia and hydrogen, causing potential fire and explosion.

What is Chlorine used for

Water chlorination began in Sweden during the 18th century with the purpose to remove odours from water. This method continued to be used solely to remove odours from water until 1890 when chlorine was identified as an effective substance for disinfection purposes. Chlorine was first used for disinfection purposes in Great Britain in the early 1900’s which over the next century chlorination became the more favoured method used for water treatment and is now used for water treatment in most countries worldwide.

Chlorination is a method that can disinfect water with high levels of microorganisms where either chlorine or substance that contain chlorine is used to oxidise and disinfect the water. Different processes can be used to achieve safe levels of chlorine in drinking water to prevent against waterborne diseases.

Why Do I Need To Detect Chlorine

Chlorine, being denser than air, tends to disperse throughout low-lying zones in poorly ventilated or stagnant areas. Although non-flammable by itself, chlorine can become explosive when in contact with substances like ammonia, hydrogen, natural gas, and turpentine.

The reaction of the human body to chlorine depends on several factors; the concentration of chlorine present in air, the duration and frequency of exposure. Effects are also dependant on the health of an individual and the environmental conditions during exposure. For example, when small amounts of chlorine are breathed in during short time periods, this can affect the respirational system. Other effects vary from coughing and chest pains, to fluid accumulation in the lungs, skin and eye irritations. To note, these effects do not take place under natural conditions.

Our solution

The use of a chlorine gas detector provides detection and measurement of this substance in the air to prevent any accidents. Equipped with an electrochemical chlorine sensor, a fixed, or portable, single gas or multi gas Cl2 detector will monitor chlorine concentration in the ambient air. We have a wide range of gas detection products to help you meet the demands of the water treatment industry.

Fixed gas detectors are ideal to monitor and alert water treatment plant managers and workers to the presence of all the major gas hazards. The fixed gas detectors can be permanently positioned inside water tanks, sewage systems, and any other areas that present a high risk of gas exposure.

Portable gas detectors are lightweight and robust wearable gas detection devices. The portable gas detectors sound and signal an alert to workers when gas levels are reaching dangerous concentrations, allowing action to be taken. Our Gasman, and Gas-Pro portables have reliable chlorine sensor options, for single gas monitoring and multi-gas monitoring.

Control panels can be applied to coordinate numerous fixed gas detection devices and provide a trigger for alarm systems.

For more information about gas detection within water and water treatment, or to explore more of Crowcon’s gas detection range, please get in touch.

Industry Overview: Battery Power

Batteries are effective at reducing power outages since they can also store excess traditional grid energy. The energy stored within batteries can be released whenever a large volume of power is needed, such as during a power failure at a data centre to prevent data being lost, or as a back-up power supply to a hospital or military application to ensure the continuity of vital services. Large scale batteries can also be used to plug short-term gaps in demand from the grid. These battery compositions can also be used in smaller sizes to power electric cars and may be further scaled down to power commercial products, such as phones, tablets, laptops, speakers and – of course – personal gas detectors.

Applications include battery storage, transportation and welding and can be segregated into four main categories: Chemical – e.g., ammonia, hydrogen, methanol and synthetic fuel, electrochemical – lead acid, lithium ion, Na-Cd, Na-ion, electrical – supercapacitors, superconductive magnetic storage and Mechanical – compressed air, pumped hydro, gravity.

Gas Hazards

Li-ion battery fires

A major concern arises when static electricity or a faulty charger damages the battery protection circuit. This damage can result in fusing the solid-state switches into an ON position, without the user knowing. A battery with a faulty protection circuit may function normally, however, may not provide protection from short circuit. A gas detection system can establish if there is a fault and may be used in a feedback loop to shut off power, seal the space and release an inert gas (such as nitrogen) into the area to prevent any fire or explosion.

Leakage of toxic gases prior to thermal runaway

Thermal runaway of lithium-metal and lithium-ion cells has resulted in several fires. With research showing that fires fuelled by flammable gases are vented from the batteries during thermal runaway. The electrolyte in a lithium-ion battery is flammable and generally contains lithium hexafluorophosphate (LiPF6) or other Li-salts containing fluorine. In the event of overheating, the electrolyte will evaporate and eventually be vented out from the battery cells. Researchers have found that commercial lithium-ion batteries can emit considerable amounts of hydrogen fluoride (HF) during a fire, and that emission rates vary for different types of battery and state of-charge (SOC) levels. Hydrogen fluoride can penetrate skin to affect deep skin tissue and even bone and blood. Even with minimal exposure, pain and symptoms may not present for several hours, by which time damage is extreme.

Hydrogen and explosion risk

With hydrogen fuel cells gaining popularity as alternatives to fossil fuel, it is important to be aware of the dangers of hydrogen. Like all fuels, hydrogen is highly flammable and if it leaks there is real risk of fire. Traditional lead acid batteries produce hydrogen when they are being charged. These batteries are normally charged together, sometimes in the same room or area, which can generate an explosion risk, especially if the room is not properly ventilated. Most hydrogen applications cannot use odorants for safety, as hydrogen disperses faster than odorants do. There are applicable safety standards for hydrogen fuelling stations, whereby appropriate protective gear is required for all workers. This includes personal detectors, capable of detecting ppm level hydrogen as well as %LEL level. The default alarm levels are set at 20% and 40% LEL which is 4% volume, but some applications may wish to have a custom PPM range and alarm levels to pick up hydrogen accumulations quickly.

To find out more on the dangers of gas hazards in battery power visit our industry page for more information.

A brief history of gas detection 

The evolution of gas detection has changed considerably over the years. New, innovative ideas from canaries to portable monitoring equipment provides workers with continuous precise gas monitoring. 

The Industrial Revolution was the catalyst in the development in gas detection due to the use of fuel that showed great promise, such as coal. As coal can be extracted from the earth through either mining or underground mining, tools like helmets and flame lights were their only protection from the dangers of methane exposure underground that were yet to be discovered. Methane gas is colourless and odourless, making it hard to know it’s presence until a noticeable pattern of health problems was discovered. The risks of gas exposure resulted in experimenting with detection methods to preserve the safety of the workers for years to come. 

A Need for Gas Detection 

Once gas exposure became apparent, miners understood that they needed to know whether the mine had any pocket of methane gas where they were working. In the early 19th century, the first gas detector was recorded with many miners wearing flame lights on their helmets to be able to see while they were working, so being able to detect the extremely flammable methane was paramount. The worker would wear a thick, wet blanket over their bodies while carrying a long wick with the end lit on fire. Entering the mines, the individual would move the flame around and along the walls looking for gas pockets. If found, a reaction would ignite and be noted to the crew while the person detecting was protected from the blanket. With time, more advanced methods of detecting gas were developed. 

The Introduction of Canaries 

Gas detection moved from humans to canaries due to their loud chirps and similar nervous systems for controlling breathing patterns. The canaries were placed in certain areas of the mine, from there, workers would check on the canaries to care for them as well as see if their health had been affected. During the work shifts, miners would listen to the canaries chirp. If a canaries began to shake its cage, that was a strong indicator of a gas pocket exposure in which it has started to affect its health. Miners would then evacuate the mine and noted that it was unsafe to enter. On some occasions if the canary stopped chirping all together, miners knew to make a swifter exit before the gas exposure had a chance to affect their health. 

The Flame Light 

The flame light was the next evolution for gas detection in the mine, as a result of worries about animal safety. Whilst providing light for the miners, the flame was housed in a flame-arrestor shell which absorbed any heat and captured the flame to prevent it from igniting any methane that may be present. The outside shell contained a glass piece with three incisions running horizontally. The middle line was set as the ideal gas environment while the bottom line indicated an oxygen-deficient environment, and the top line indicated methane exposure or an oxygen-enriched environment. Miners would light the flame in an environment with fresh air. If the flame lowered or started to die, it would indicate that the atmosphere had a low oxygen concentration. If the flame grew larger, the miners knew that methane was present with oxygen, both cases indicating that they needed to leave the mine. 

The Catalytic Sensor 

Although the flame light was a development in gas detection technology, it however, was not a ‘one size fits all’ approach for all industries. Therefore, the catalytic sensor was the first gas detector that has a resemblance to modern technology. The sensors work on the principle that when a gas oxidises, it produces heat. The catalytic sensor works through temperature change, which is proportional to the concentration of gas. Whilst this was a step forward in the development of the technology required for gas detection, it still initially required manual operation in order to receive a reading. 

Modern Day Technology 

Gas detection technology has been developed tremendously since the early 19th century in which the first gas detector was recorded. With now over five different types of sensors commonly used across all industries, including Electrochemical, Catalytic Beads (Pellistor), Photoionisation detector (PID) and Infrared Technology (IR), along with the most modern sensors Molecular Property Spectrometer™ (MPS) and Long-Life Oxygen (LLO2), modern day gas detectors are highly sensitive, accurate but most importantly reliable, all of which allow for all personnel to stay safe reducing the number of workplace fatalities. 

How do Electrochemical sensors work? 

Electrochemical sensors are the most used in diffusion mode in which gas in the ambient environment enters through a hole in the face of the cell. Some instruments use a pump to supply air or gas samples to the sensor. A PTFE membrane is fitted over the hole to prevent water or oils from entering the cell. Sensor ranges and sensitivities can be varied in design by using different size holes. Larger holes provide higher sensitivity and resolution, whereas smaller holes reduce sensitivity and resolution but increase the range.  

Benefits  

Electrochemical sensors have several benefits.  

  • Can be specific to a particular gas or vapor in the parts-per-million range. However, the degree of selectivity depends on the type of sensor, the target gas and the concentration of gas the sensor is designed to detect.  
  • High repeatability and accuracy rate. Once calibrated to a known concentration, the sensor will provide an accurate reading to a target gas that is repeatable. 
  • Not susceptible to poisoning by other gases, with the presence of other ambient vapours will not shorten or curtail the life of the sensor. 
  • Less expensive than most other gas detection technologies, such as IR or PID technologies. Electrochemical sensors are also more economical. 

Issues with cross-sensitivity  

Cross-sensitivity occurs when a gas other than the gas being monitored/detected can affect the reading given by an electrochemical sensor. This causes the electrode within the sensor to react even if the target gas is not actually present, or it causes an otherwise inaccurate reading and/or alarm for that gas. Cross-sensitivity may cause several types of inaccurate reading in electrochemical gas detectors. These can be positive (indicating the presence of a gas even though it is not actually there or indicating a level of that gas above its true value), negative (a reduced response to the target gas, suggesting that it is absent when it is present, or a reading that suggests there is a lower concentration of the target gas than there is), or the interfering gas can cause inhibition. 

Factors affecting electrochemical sensor life  

There are three main factors that affect the sensor life including temperature, exposure to extremely high gas concentrations and humidity. Other factors include sensor electrodes and extreme vibration and mechanical shocks. 

Temperature extremes can affect sensor life. The manufacturer will state an operating temperature range for the instrument: typically -30˚C to +50˚C. High quality sensors will, however, be able to withstand temporary excursions beyond these limits. Short (1-2 hours) exposure to 60-65˚C for H2S or CO sensors (for example) is acceptable, but repeated incidents will result in evaporation of the electrolyte and shifts in the baseline (zero) reading and slower response.  

Exposure to extremely high gas concentrations can also compromise sensor performance. Electrochemical sensors are typically tested by exposure to as much as ten-times their design limit. Sensors constructed using high quality catalyst material should be able to withstand such exposures without changes to chemistry or long-term performance loss. Sensors with lower catalyst loading may suffer damage. 

The most considerable influence on sensor life is humidity. The ideal environmental condition for electrochemical sensors is 20˚Celsius and 60% RH (relative humidity). When the ambient humidity increases beyond 60%RH water will be absorbed into the electrolyte causing dilution. In extreme cases the liquid content can increase by 2-3 times, potentially resulting in leakage from the sensor body, and then through the pins. Below 60%RH water in the electrolyte will begin to de-hydrate. The response time may be significantly extended as the electrolyte or dehydrated. Sensor electrodes can in unusual conditions be poisoned by interfering gases that adsorb onto the catalyst or react with it creating by-products which inhibit the catalyst. 

Extreme vibration and mechanical shocks can also harm sensors by fracturing the welds that bond the platinum electrodes, connecting strips (or wires in some sensors) and pins together. 

‘Normal’ life expectancy of electrochemical Sensor  

Electrochemical sensors for common gases such as carbon monoxide or hydrogen sulphide have an operational life typically stated at 2-3 years. More exotic gas sensor such as hydrogen fluoride may have a life of only 12-18 months. In ideal conditions (stable temperature and humidity in the region of 20˚C and 60%RH) with no incidence of contaminants, electrochemical sensors have been known to operate more than 4000 days (11 years). Periodic exposure to the target gas does not limit the life of these tiny fuel cells: high quality sensors have a large amount of catalyst material and robust conductors which do not become depleted by the reaction. 

Products  

As electrochemical sensors are more economical, We have a range of portable products and fixed products that use this type of sensor to detect gases.  

To explore more, visit our technical page for more information. 

How Long will my Gas Sensor Last?

Gas detectors are used extensively within many industries (such as water treatment, refinery, petrochemical, steel and construction to name a few) to protect personnel and equipment from dangerous gases and their effects. Users of portable and fixed devices will be familiar with the potentially significant costs of keeping their instruments operating safely over their operational life. Gas sensors are understood to provide a measurement of the concentration of some analyte of interest, such as CO (carbon monoxide), CO2 (carbon dioxide), or NOx (nitrogen oxide). There are two most used gas sensors within industrial applications: electrochemical for toxic gases and oxygen measurement, and pellistors (or catalytic beads) for flammable gases. In recent years, the introduction of both Oxygen and MPS (Molecular Property Spectrometer) sensors have allowed for improved safety.  

How do I know when my sensor has failed? 

There have been several patents and techniques applied to gas detectors over the past few decades which claim to be able to determine when an electrochemical sensor has failed. Most of these however, only infer that the sensor is operating through some form of electrode stimulation and might provide a false sense of security. The only sure method of demonstrating that a sensor is working is to apply test gas and measure the response: a bump test or full calibration. 

Electrochemical Sensor  

Electrochemical sensors are the most used in diffusion mode in which gas in the ambient environment enters through a hole in the face of the cell. Some instruments use a pump to supply air or gas samples to the sensor. A PTFE membrane is fitted over the hole to prevent water or oils from entering the cell. Sensor ranges and sensitivities can be varied in design by using different size holes. Larger holes provide higher sensitivity and resolution, whereas smaller holes reduce sensitivity and resolution but increase the range. 

Factors affecting Electrochemical Sensor Life 

There are three main factors that affect the sensor life including temperature, exposure to extremely high gas concentrations and humidity. Other factors include sensor electrodes and extreme vibration and mechanical shocks.  

Temperature extremes can affect sensor life. The manufacturer will state an operating temperature range for the instrument: typically -30˚C to +50˚C. High quality sensors will, however, be able to withstand temporary excursions beyond these limits. Short (1-2 hours) exposure to 60-65˚C for H2S or CO sensors (for example) is acceptable, but repeated incidents will result in evaporation of the electrolyte and shifts in the baseline (zero) reading and slower response. 

Exposure to extremely high gas concentrations can also compromise sensor performance. Electrochemical sensors are typically tested by exposure to as much as ten-times their design limit. Sensors constructed using high quality catalyst material should be able to withstand such exposures without changes to chemistry or long-term performance loss. Sensors with lower catalyst loading may suffer damage.  

The most considerable influence on sensor life is humidity. The ideal environmental condition for electrochemical sensors is 20˚Celsius and 60% RH (relative humidity). When the ambient humidity increases beyond 60%RH water will be absorbed into the electrolyte causing dilution. In extreme cases the liquid content can increase by 2-3 times, potentially resulting in leakage from the sensor body, and then through the pins. Below 60%RH water in the electrolyte will begin to de-hydrate. The response time may be significantly extended as the electrolyte or dehydrated. Sensor electrodes can in unusual conditions be poisoned by interfering gases that adsorb onto the catalyst or react with it creating by-products which inhibit the catalyst.  

Extreme vibration and mechanical shocks can also harm sensors by fracturing the welds that bond the platinum electrodes, connecting strips (or wires in some sensors) and pins together.  

‘Normal’ Life Expectancy of Electrochemical Sensor 

Electrochemical sensors for common gases such as carbon monoxide or hydrogen sulphide have an operational life typically stated at 2-3 years. More exotic gas sensor such as hydrogen fluoride may have a life of only 12-18 months. In ideal conditions (stable temperature and humidity in the region of 20˚C and 60%RH) with no incidence of contaminants, electrochemical sensors have been known to operate more than 4000 days (11 years). Periodic exposure to the target gas does not limit the life of these tiny fuel cells: high quality sensors have a large amount of catalyst material and robust conductors which do not become depleted by the reaction. 

Pellistor Sensor 

Pellistor sensors consist of two matched wire coils, each embedded in a ceramic bead. Current is passed through the coils, heating the beads to approximately 500˚C. Flammable gas burns on the bead and the additional heat generated produces an increase in coil resistance which is measured by the instrument to indicate gas concentration. 

Factors affecting Pellistor Sensor Life 

The two main factors that affect the sensor life include exposure to high gas concentration and poising or inhibition of the sensor. Extreme mechanical shock or vibration can also affect the sensor life. The capacity of the catalyst surface to oxidise the gas reduces when it has been poisoned or inhibited. Sensor life more than ten years is common in applications where inhibiting or poisoning compounds are not present. Higher power pellistors have greater catalytic activity and are less vulnerable to poisoning. More porous beads also have greater catalytic activity as their surface volume in increased. Skilled initial design and sophisticated manufacturing processes ensure maximum bead porosity. Exposure to high gas concentrations (>100%LEL) may also compromise sensor performance and create an offset in the zero/base-line signal. Incomplete combustion results in carbon deposits on the bead: the carbon ‘grows’ in the pores and creates mechanical damage. The carbon may however be burned off over time to re-reveal catalytic sites. Extreme mechanical shock or vibration can in rare cases also cause a break in the pellistor coils. This issue is more prevalent on portable rather than fixed-point gas detectors as they are more likely to be dropped, and the pellistors used are lower power (to maximise battery life) and thus use more delicate thinner wire coils. 

How do I know when my sensor has failed? 

A pellistor that has been poisoned remains electrically operational but may fail to respond to gas. Hence the gas detector and control system may appear to be in a healthy state, but a flammable gas leak may not be detected. 

Oxygen Sensor 

Long Life 02 Icon

Our new lead-free, long-lasting oxygen sensor does not have compressed strands of lead the electrolyte has to penetrate, allowing a thick electrolyte to be used which means no leaks, no leak induced corrosion, and improved safety. The additional robustness of this sensor allows us to confidently offer a 5-year warranty for added piece of mind. 

Long life-oxygen sensors have an extensive lifespan of 5-years, with less downtime, lower cost of ownership, and reduced environmental impact. They accurately measure oxygen over a broad range of concentrations from 0 to 30% volume and are the next generation of O2 gas detection. 

MPS Sensor  

MPS sensor provides advanced technology that removes the need to calibrate and provides a ‘True LEL (lower explosive limit)’ for reading for fifteen flammable gases but can detect all flammable gases in a multi-species environment, resulting in lower ongoing maintenance costs and reduced interaction with the unit. This reduces risk to personnel and avoids costly downtime. The MPS sensor is also immune to sensor poisoning.  

Sensor failure due to poisoning can be a frustrating and costly experience. The technology in the MPS™ sensor is not affected by contaminates in the environment. Processes that have contaminates now have access to a solution that operates reliably with fail safe design to alert operator to offer a peace of mind for personnel and assets located in hazardous environment. It is now possible to detect multiple flammable gases, even in harsh environments, using just one sensor that does not require calibration and has an expected lifespan of at least 5 years.