The importance of Gas Detection in the Water and Wastewater Industry 

Water is vital to our daily lives, both for personal and domestic use and industrial/commercial applications. Whether a facility focuses on the production of clean, potable water or treating effluent, Crowcon is proud to serve a wide variety of water industry clients, providing gas detection equipment that keeps workers safe around the world. 

Gas Hazards 

Apart from common gas hazards known in the industry; methane, hydrogen sulphide, and oxygen, there are bi-product gas hazards and cleaning material gas hazards that occur from purifying chemicals such as ammonia, chlorine, chlorine dioxide or ozone that are used in the decontamination of the waste and effluent water, or to remove microbes from clean water. There is great potential for many toxic or explosive gases to exist as a result of the chemicals used in the water industry. And added to these are chemicals that may be spilled or dumped into the waste system from industry, farming or building work. 

Safety Considerations  

Confined Space Entry 

The pipelines used to transport water require regular cleaning and safety checks; during these operations, portable multi-gas monitors are used to protect the workforce. Pre-entry checks must be completed prior to entering any confined space and commonly O2, CO, H2S and CH4 are monitored. Confined spaces are small, so portable monitors must be compact and unobtrusive for the user, yet able to withstand the wet and dirty environments in which they must perform. Clear and prompt indication of any increase in gas monitored (or any decrease for oxygen) is of paramount importance – loud and bright alarms are effective in raising the alarm to the user. 

Risk assessment 

Risk assessment is critical, as you need to be aware of the environment that you are entering and thus working in. Therefore, understanding the applications and identifying the risks regarding all safety aspects. Focusing on gas monitoring, as part of the risk assessment, you need to be clear on what gases may be present.  

Fit for purpose 

There is a variety of applications within the water treatment process, giving the need to monitor multiple gases, including carbon dioxide, hydrogen sulphide, chlorine, methane, oxygen, ozone and chlorine dioxide. Gas detectors are available for single or multiple gas monitoring, making them practical for different applications as well as making sure that, if conditions change (such as sludge is stirred up, causing a sudden increase in hydrogen sulphide and flammable gas levels), the worker is still protected.  

Legislation   

European Commission Directive 2017/164 issued in January 2017, established a new list of indicative occupational exposure limit values (IOELVs). IOELV are health-based, non-binding values, derived from the most recent scientific data available and considering the availability of reliable measurement techniques. The list includes carbon monoxide, nitrogen monoxide, nitrogen dioxide, sulphur dioxide, hydrogen cyanide, manganese, diacetyl and many other chemicals. The list is based on Council Directive 98/24/EC that considers the protection of the health and safety of workers from the risks related to chemical agents in the workplace. For any chemical agent for which an IOELV has been set at Union level, Member States are required to establish a national occupational exposure limit value. They also are required to take into account the Union limit value, determining the nature of the national limit value in accordance with national legislation and practice. Member States will be able to benefit from a transitional period ending at the latest on 21 August 2023.  

The Health and Safety Executive (HSE) state that each year several workers will suffer from at least one episode of work-related illness. Although, most illnesses are relatively mild cases of gastroenteritis, there is also a risk for potentially fatal diseases, such as leptospirosis (Weil’s disease) and hepatitis. Even though these are reported to the HSE, there could be significant under-reporting as there is often failure to recognise the link between illness and work.  

Under domestic law of the Health and Safety at Work etc Act 1974, employers are responsible for ensuring the safety of their employees and others. This responsibility is reinforced by regulations. 

The Confined Spaces Regulations 1997 applies where the assessment identifies risks of serious injury from work in confined spaces. These regulations contain the following key duties: 

  • Avoid entry to confined spaces, e.g., by doing the work from the outside. 
  • If entry to a confined space is unavoidable, follow a safe system of work.
  • Put in place adequate emergency arrangements before the work start. 

The Management of Health and Safety at Work Regulations 1999 requires employers and self-employed people to carry out a suitable and sufficient assessment of the risks for all work activities for the purpose of deciding what measures are necessary for safety. For work in confined spaces this means identifying the hazards present, assessing the risks and determining what precautions to take. 

Our solutions

Elimination of these gas hazards is virtually impossible, so permanent workers and contractors must depend on reliable gas detection equipment to protect them. Gas detection can be provided in both fixed and portable forms. Our portable gas detectors protect against a wide range of gas hazards, these include T4x, Clip SGD, Gasman, Tetra 3,Gas-Pro, T4 and Detective+. Our fixed gas detectors are used in many applications where reliability, dependability and lack of false alarms are instrumental to efficient and effective gas detection, these include Xgard, Xgard Bright and IRmax. Combined with a variety of our fixed detectors, our gas detection control panels offer a flexible range of solutions that measure flammable, toxic and oxygen gases, report their presence and activate alarms or associated equipment, for the wastewater industry our panels include  Gasmaster.    

To find out more on the gas hazards in wastewater and water treatment visit our industry page for more information.  

Gold Mining: What gas detection do I need? 

How is gold mined?

Gold is a rare substance equating to 3 parts per billion of the earth’s outer layer, with most of the world’s available gold coming from Australia. Gold, like iron, copper and lead, is a metal. There are two primary forms of gold mining, including open-cut and underground mining. Open mining involves earth-moving equipment to remove waste rock from the ore body above, and then mining is conducted from the remaining substance. This process requires waste and ore to be struck at high volumes to break the waste and ore into sizes suitable for handling and transportation to both waste dumps and ore crushers. The other form of gold mining is the more traditional underground mining method. This is where vertical shafts and spiral tunnels transport workers and equipment into and out of the mine, providing ventilation and hauling the waste rock and ore to the surface.

Gas detection in mining

When relating to gas detection, the process of health and safety within mines has developed considerably over the past century, from morphing from the crude usage of methane wick wall testing, singing canaries and flame safety to modern-day gas detection technologies and processes as we know them. Ensuring the correct type of detection equipment is utilised, whether fixed or portable, before entering these spaces. Proper equipment utilisation will ensure gas levels are accurately monitored, and workers are alerted to dangerous concentrations within the atmosphere at the earliest opportunity.

What are the gas hazards and what are the dangers?

The dangers those working within the mining industry face several potential occupational hazards and diseases, and the possibility of fatal injury. Therefore, understanding the environments and hazards, they may be exposed to is important.

Oxygen (O2)

Oxygen (O2), usually present in the air at 20.9%, is essential to human life. There are three main reasons why oxygen poses a threat to workers within the mining industry. These include oxygen deficiencies or enrichment, as too little oxygen can prevent the human body from functioning leading to the worker losing consciousness. Unless the oxygen level can be restored to an average level, the worker is at risk of potential death. An atmosphere is deficient when the concentration of O2 is less than 19.5%. Consequently, an environment with too much oxygen is equally dangerous as this constitutes a greatly increased risk of fire and explosion. This is considered when the concentration level of O2 is over 23.5%

Carbon Monoxide (CO)

In some cases, high concentrations of Carbon Monoxide (CO) may be present. Environments that this may occur include a house fire, therefore the fire service are at risk of CO poisoning. In this environment there can be as much as 12.5% CO in the air which when the carbon monoxide rises to the ceiling with other combustion products and when the concentration hits 12.5% by volume this will only lead to one thing, called a flashover. This is when the whole lot ignites as a fuel. Apart from items falling on the fire service, this is one of the most extreme dangers they face when working inside a burning building. Due to the characteristics of CO being so hard to identify, I.e., colorless, odourless, tasteless, poisonous gas, it may take time for you to realise that you have CO poisoning. The effects of CO can be dangerous, this is because CO prevents the blood system from effectively carrying oxygen around the body, specifically to vital organs such as the heart and brain. High doses of CO, therefore, can cause death from asphyxiation or lack of oxygen to the brain. According to statistics from the Department of Health, the most common indication of CO poisoning is that of a headache with 90% of patients reporting this as a symptom, with 50% reporting nausea and vomiting, as well as vertigo. With confusion/changes in consciousness, and weakness accounting for 30% and 20% of reports.

Hydrogen sulphide (H2S)

Hydrogen sulphide (H2S) is a colorless, flammable gas with a characteristic odour of rotten eggs. Skin and eye contact may occur. However, the nervous system and cardiovascular system are most affected by hydrogen sulphide, which can lead to a range of symptoms. Single exposures to high concentrations may rapidly cause breathing difficulties and death.

Sulphur dioxide (SO2)

Sulphur dioxide (SO2) can cause several harmful effects on the respiratory systems, in particular the lung. It can also cause skin irritation. Skin contact with (SO2) causes stinging pain, redness of the skin and blisters. Skin contact with compressed gas or liquid can cause frostbite. Eye contact causes watering eyes and, in severe cases, blindness can occur.

Methane (CH4)

Methane (CH4) is a colorless, highly flammable gas with a primary component being that of natural gas. High levels of (CH4) can reduce the amount of oxygen breathed from the air, which can result in mood changes, slurred speech, vision problems, memory loss, nausea, vomiting, facial flushing and headache. In severe cases, there may be changes in breathing and heart rate, balance problems, numbness, and unconsciousness. Although, if exposure is for a longer period, it can result in fatality.

Hydrogen (H2)

Hydrogen Gas is a colorless, odourless, and tasteless gas which is lighter than air. As it is lighter than air this means it float higher than our atmosphere, meaning it is not naturally found, but instead must be created. Hydrogen poses a fire or explosion risk as well as an inhalation risk. High concentrations of this gas can cause an oxygen-deficient environment. Individuals breathing such an atmosphere may experience symptoms which include headaches, ringing in ears, dizziness, drowsiness, unconsciousness, nausea, vomiting and depression of all the senses

Ammonia (NH3)

Ammonia (NH3) is one of the most widely used chemicals globally that is produced both in the human body and in nature. Although it is naturally created (NH3) is corrosive which poses a serve concern for health. High exposure within the air can result in immediate burning to the eyes, nose, throat and respiratory tract. Serve cases can result in blindness.

Other gas risks

Whilst Hydrogen Cyanide (HCN) doesn’t persist within the environment, improper storage, handling and waste management can pose severe risk to human health as well as effects on the environment. Cyanide interferes with human respiration at cellular levels that can cause serve and acute effects, including rapid breathing, tremors, asphyxiation.

Diesel particulate exposure can occur in underground mines as a result of diesel-powered mobile equipment used for drilling and haulage. Although control measures include the use of low sulphur diesel fuel, engine maintenance and ventilation, health implication includes excess risk of lung cancer.

Products that can help to protect yourself

Crowcon provide a range of gas detection including both portable and fixed products all of which are suitable for gas detection within the mining industry.

To find out more visit our industry page here.

What causes Hydrocarbon Fires?  

Hydrocarbon fires are caused by fuels containing carbon being burned in oxygen or air. Most fuels contain significant levels of carbon, including paper, petrol, and methane – as examples of solid, liquid or gaseous fuels – hence hydrocarbon fires. 

For there to be an explosion risk there needs to be at least 4.4% methane in air or 1.7% propane, but for solvents as little as 0.8 to 1.0% of the air being displaced can be enough to create a fuel air mix that will explode violently on contact with any spark.

Dangers associated with hydrocarbon fires

Hydrocarbon fires are considered highly dangerous when compared to fires that have ignited as a result of simple combustibles, as these fires have the capacity to burn at a larger scale as well as also having the potential to trigger an explosion if the fluids released cannot be controlled or contained. Therefore, these fires pose a dangerous threat to anyone who works in a high-risk area, the dangers include energy related dangers such as burning, incineration of surrounding objects. This is a danger due to the ability that the fires can grow quickly, and that heat can be conducted, converted and radiated to new sources of fuel causing secondary fires. 

Toxic hazards may be present in combustion products, for example, carbon monoxide (CO), hydrogen cyanide (HCN), hydrochloric acid (HCL), nitrogen dioxide (NO2) and various polycyclic aromatic hydrocarbons (PAH) compounds are dangerous for those working in these environments. CO uses the oxygen that is used to transport the red blood cells around the body, at least temporarily, impairing the body’s ability to transport oxygen from our lungs to the cells that need it. HCN adds to this problem by inhibiting the enzyme that tells the red blood cells to let go of the oxygen they have where it is needed – further inhibiting the body’s ability to get the oxygen to the cells that need it. HCL is a generally an acidic compound that is created through overheated cables. This is harmful to the body if ingested as it affects the lining of the mouth, nose, throat, airways, eyes, and lungs. NO2 is created in high temperature combustion and that can cause damage to the human respiratory tract and increase a person’s vulnerability to and in some cases lead to asthma attacks. PAH’s affects the body over a longer period of time, with serve cases leading to cancers and other illnesses. 

We can look up the relevant health levels accepted as workplace safety limits for healthy workers within Europe and the permissible exposure limits for the United States. This gives us a 15-minute time weighted average concentration and an 8-hour time weighted average concentration. 

For the gases these are: 

Gas  STEL (15-minute TWA)  LTEL (8-hour TWA)  LTEL (8hr TWA) 
CO  100ppm  20ppm  50ppm 
NO2  1ppm  0.5ppm  5 Ceiling Limit 
HCL  1ppm  5ppm  5 Ceiling Limit 
HCN  0.9ppm  4.5ppm  10ppm 

The different concentrations represent the different gas risks, with lower numbers needed for more dangerous situations. Fortunately, the EU has worked it all out for us and turned it into their EH40 standard. 

Ways of protecting ourselves

We can take steps to ensure we do not suffer from exposure to fires or their unwanted combustion products. Firstly of course, we can adhere to all fire safety measures, as is the law. Secondly, we can take a pro-active approach and not let potential fuel sources accumulate. Lastly, we can detect and warn of the presence of combustion products using appropriate gas detection equipment. 

Crowcon product solutions

Crowcon provides a range of equipment capable of detecting fuels and the combustion products described above. Our PID products detect solids and liquid-based fuels once they are airborne, as either hydrocarbons on dust particles or solvent vapours. This equipment includes our GasPro portable. The gases can be detected by our Gasman single gas, T3 multi gas and Gas-Pro multi gas pumped portable products, and our Xgard, Xgard Bright and Xgard IQ fixed products – each of which has the capability of detecting all the gases mentioned. 

Keeping the Emergency Services/First Responders Safe

Emergency Service Personnel/First Responders encounter gas related risks as part of their jobs. However, immediate evaluation of their surrounds is key upon arrival as well as continuous monitoring whilst in a rescue situation are vital for the health of all those involved.  

What Gases are Present?

Toxic gases like carbon monoxide (CO) and hydrogen cyanide (HCN) are present if there is a fire. Individually these gases are dangerous and even deadly, the two combined is exponentially worse, known as the toxic twins.  

Carbon monoxide (CO) is a colorless, odourless, tasteless, poisonous gas produced by incomplete burning of carbon-based fuels, including gas, oil, wood, and coal. It is only when fuel does not burn fully that excess CO is produced, which is poisonous. When the excess CO enters the body, it stops the blood from bringing oxygen to cells, tissues, and organs. CO is poisonous as you cannot see it, taste it or smell it but CO can kill quickly without warning.  

Hydrogen Cyanide (HCN) is an important industrial chemical and over a million tonnes are produced globally each year. Hydrogen Cyanide (HCN) is a colorless or light blue liquid or gas that is extremely flammable. It has a faint bitter almond odour, although this isn’t detectable to everyone.  There are many uses for hydrogen cyanide, primarily in the manufacture of paints, plastics, synthetic fibres (for example nylon) and other chemicals. Hydrogen cyanide and other cyanide compounds have also been used as a fumigant to control pests. With other uses being in metal cleaning, gardening, ore-extraction, electroplating, dying, printing and photography. Sodium and potassium cyanide and other cyanide salts may be made from hydrogen cyanide. 

What are the risks?

These gases are dangerous individually. However, exposure to both combined is even more dangerous, so an adequate CO and HCN gas detector is essential where the toxic twins are found. Usually, visible smoke is a good guide, however the Toxic Twins are both colorless.  Combined these gases are usually found in fires. in which, Firefighters and other Emergency Personnel are trained to look out for CO poisoning in fires. However, due to the increased use of plastics and man-made fibres, HCN can be released at up to 200ppm in domestic and industrial fires. These two gases cause thousands of fire related deaths annually, so needs more consideration in fire gas detection.  

The attendance of HCN in the environment may not always lead to exposure. However, for HCN to cause any adverse health effects, you need to come into contact with it, i.e., breathing, eating, drinking, or through skin or eye contact with it. Following exposure to any chemical, the adverse health effects are dependent on a number of factors, such as the amount to which you are exposed (dose), the way you are exposed, the duration of exposure, the form of the chemical and if you were exposed to any other chemicals. As HCN is very toxic, it can prevent the body from using oxygen properly. Early signs of exposure to HCN include headache, sickness, dizziness, confusion and even drowsiness. Substantial exposure may rapidly lead to unconsciousness, fitting, coma and possibly death. If a substantial exposure is survived, there may be long-term effects from damage to the brain and other nervous system damage. Effects from skin contact require a large surface of the skin in order to be exposed. 

What Products are Available?

For Emergency Service Teams/First Responders, the use of portable gas detectors is essential. Toxic gases are produced when materials are burnt meaning flammable gases and vapours may be present.  

Our Gas-Pro portable multi gas detector offers detection of up to 5 gases in a compact and rugged solution. It has an easy-to-read top mount display making it easy to use and optimal for confined space gas detection. An optional internal pump, activated with the flow plate, takes the pain out of pre-entry testing and allows Gas-Pro to be worn either in pumped or diffusion modes. In-field pellistor changes for methane, hydrogen, propane, ethane, acetylene (0–100% LEL, with resolution of 1% LEL). By allowing in-field pellistor changes, Gas-Pro detectors give users the flexibility to conveniently test for a range of flammable gases, without needing multiple sensors or detectors. What is more, they can continue to calibrate using existing methane canisters, saving time and money. The gas sensor for hydrogen cyanide has a monitoring measuring range of 0–30 ppm with resolution of 0.1 ppm.  

Tetra 3 portable multi gas monitor can detect and monitor the four most common gases (carbon monoxide, methane, oxygen and hydrogen sulphide), but also an expanded range: ammonia, ozone, sulphur dioxide, H2 filtered CO (for steel plants) and IR carbon dioxide (for safe area use only). 

T4 portable 4-in-1 gas detector provides effective protection against 4 common gas hazards: carbon monoxide, hydrogen sulphide, flammable gases and oxygen depletion. The T4 multi gas detector now comes with improved detection of pentane, hexane and other long chain hydrocarbons. 

Clip Single Gas Detector (SDG) is an industrial gas detector designed for use in hazardous areas and offers reliable and durable fixed life span monitoring in a compact, lightweight and maintenance-free package. Clip SGD has a 2-year life and is available for hydrogen sulphide (H2S), carbon monoxide (CO) or oxygen (O2). 

Gasman is a full function device in a compact and lightweight package – perfect for customers who need more sensor options, TWA and data capability. It comes available with long-life O2 sensor, MPS sensor technology.

MPS Sensor provides advanced technology that removes the need to calibrate and provides a ‘True LEL’ for reading for fifteen flammable gases but can detect all flammable gases in a multi-species environment. Many industries and applications use or have as a by product multiple gases within the same environment. This can be challenging for traditional sensor technology which can detect only a single gas that they were calibrated for and can result in inaccurate reading and even false alarms which can halt process or production. The challenges faced in multi gas species environments can be frustrating and counterproductive. Our MPS™ sensor can accurately detect multiple gases at once and instantly identify gas type. Our MPS™ sensor has a on board environmental compensation and does not require a correctional factor. Inaccurate readings and false alarms are a thing of the past.

Crowcon Connect is a gas safety and compliance insight solution that utilises a flexible cloud data service offering actionable insight from detector fleet. This cloud-based software provides a top level view of device utilisation with dashboard showing proportion of devices that are Assigned or Unassigned to an operator, for the specific region or area selected. Fleet Insights provides overview of devices switch on/off, synced or in alarm.