Crowcon is committed to supporting users of models which have been replaced in the product line-up with spares, servicing and technical advice. After a prolonged period, limitations of parts supply will mean that support eventually ceases. If you have a specific query, your local distributor or Area Sales Manager will be able to advise of current support status.
If you know that your unit has reached the stage at which it is no longer supported, or you have an older generation of Crowcon product that has simply reached the end of its service life, and wish to know what the current replacement model is, please see the table below.
Status Definitions:
Current – New sales of product possible and spares readily available
Obsolete – Product can no longer be purchased, spares available for 5-7 years from date of obsolescence
Unsupported – Product can no longer be purchased, spares no longer available after any current stocks run out
Tragbare Monitore |
|||
Modell | Beschreibung | Status | Aktuelles Äquivalent oder Ersatzprodukt |
Dreifach Plus Plus | Portable 1-4 Gas Monitor | Aktuell | Aktuelles Produkt |
Dreifach Plus Plus IR | Tragbarer 1-4 Gasmonitor mit IR-Sensor für Kohlenwasserstoffe oder Kohlendioxid | Aktuell | Aktuelles Produkt |
Gasman | Personal Single Gas Monitor | Aktuell | Aktuelles Produkt |
Detektiv Plus | Multi-Gas Temporary Area Monitor | Aktuell | Aktuelles Produkt |
Tetra 3 | Persönlicher 1-4 Gasmonitor | Aktuell | Aktuelles Produkt |
Gasman IR CO2 | Personal IR CO2 monitor | Aktuell | Aktuelles Produkt |
Gas-Pro | Premium-Multigas-Personenmonitor | Aktuell | Aktuelles Produkt |
T4 | Personal 4 Gasmonitor | Aktuell | Aktuelles Produkt |
Clip SGD | Persönlicher Gasalarm mit fester Lebensdauer | Aktuell | Aktuelles Produkt |
LaserMethane Smart | Laser Methane Leak Detector | Aktuell | Aktuelles Produkt |
LaserMethane Mini | Laser Methane Leak Detector | Obsolete, Reduced Spares | LaserMethane Smart |
73GR | Tragbarer Monitor für brennbare Gase mit zwei Messbereichen | Nicht unterstützte | Triple Plus Plus dual range flammable |
74GC | Tragbarer Detektor für brennbare Gase | Nicht unterstützte | Gasman |
75TC | Tragbarer Wärmeleitfähigkeitsdetektor | Nicht unterstützte | Keine aktuelle Entsprechung |
76GA | Tragbarer Detektor für brennbare Gase | Nicht unterstützte | Gasman |
79OX | Tragbarer Sauerstoffdetektor | Nicht unterstützte | Gasman |
81CO | Tragbarer Kohlenmonoxid-Detektor | Nicht unterstützte | Gasman |
84GA | Portable Flammable Gas Monitor | Nicht unterstützte | Gasman |
84DL | Portable Flammable and Oxygen Monitor | Nicht unterstützte | Tetra3 |
84TR | Portable Triple Gas Monitor | Nicht unterstützte | Tetra3 |
85OX | Tragbarer Sauerstoffdetektor | Nicht unterstützte | Gasman |
88OX | Persönlicher Sauerstoffdetektor | Nicht unterstützte | Gasman |
88TX | Personal Carbon Monoxide or Hydrogen Sulphide Detector | Nicht unterstützte | Gasman |
GA4 | Tragbarer Detektor für brennbare Gase | Nicht unterstützte | Gasman |
GC4 | Tragbares Pumpengerät für brennbare Gase - nur Anzeige | Nicht unterstützte | Keine aktuelle Entsprechung |
GS4 | Tragbarer Spurengas-Leckdetektor | Nicht unterstützte | Keine aktuelle Entsprechung |
GT4 | Tragbarer Wärmeleitfähigkeitsdetektor - nur Anzeige mit Pumpe | Nicht unterstützte | Keine aktuelle Entsprechung |
Dreifach Plus | Tragbarer1-4 Gasmonitor | Nicht unterstützte | Dreifach Plus Plus |
Autokalibrator II | Automatisches Kalibrierungssystem | Nicht unterstützte | i-Test |
Original Gasman | Personal Single Gas | Nicht unterstützte | Gasman |
Detektiv | Transportable Multi-gas Monitor | Nicht unterstützte | Detektiv Plus |
Verwahrstelle | Persönlicher 1-4 Gasmonitor | Nicht unterstützte | Tetra3 |
Safegard | Personal CO2 monitor | Nicht unterstützte | Gasman IR CO2 |
Gasman II | Personal Single Gas Monitor | Nicht unterstützte | Gasman |
Eikon | Persönlicher Gasalarm mit fester Lebensdauer | Nicht unterstützte | Clip SGD |
Tetra | Persönlicher 1-4 Gasmonitor | Nicht unterstützte | T4 or Tetra 3 |
Kontrollkästchen | Mehrkanaliges Kalibrierungs- und Wartungssystem | Nicht unterstützte | i-Test |
Detective NET Drahtlos | Drahtloser Multigas-Zeitbereichsmonitor | Nicht unterstützte | Detective+ (mit drahtgebundener Kommunikation) |
Crowcon-Clip | Persönlicher Gasalarm mit fester Lebensdauer | Nicht unterstützte | Clip SGD |
Feste Monitore |
|||
Fixed Gas Detectors (‘heads’) |
|||
Modell | Beschreibung | Status | Aktuelles Äquivalent oder Ersatzprodukt |
96HD | Sensorgehäuse für Pellistoren, E'chem-Sensoren oder TC-Beads. | Veraltet | Xgard. Available as replacement parts for Flamgard Plus and TXgard Plus. |
DI-5/6 | Detektor für brennbare Gase (Pellistor) | Nicht unterstützte | Xgard Type 3/5 or Xgard Bright |
DI-7 | CO2-Detektor | Nicht unterstützte | Xgard IR CO2. Control, equipment will need updating. |
DI-8 | H2S-Detektor (Sulphistor) | Nicht unterstützte | Xgard Type 1/2 or Xgard IQ |
DI-9 | Detektor für brennbare Gase (abschaltbar, Pellistor) | Nicht unterstützte | Xgard Type 3 or 5 to replace the complete detector. |
DI-10 | Flammable gas detector (programmable) | Nicht unterstützte | Xgard Type 4 to replace the complete detector |
73HT | Detektor für brennbare Gase (Hochtemperatur, Pellistor) | Nicht unterstützte | Xgard Type 3 or 5 to replace the complete detector. |
81HD | Detektor für brennbare Gase (Pellistor) | Nicht unterstützte | Xgard Type 6 to replace the complete detector. |
82HD | Gasdetektor mit Wärmeleitfähigkeit | Nicht unterstützte | Xgard Type 1 to replace the complete detector |
83HD/OX | Giftgas- und Sauerstoffdetektoren (eigensicher) | Nicht unterstützte | Current re-buildable sensor housing for pellistors and electrochemical cells. Used on Flamgard Exe/D/4-20/Plus, TCgard, TXgard-D/Plus. |
Fest installierte Gasdetektoren |
|||
Modell | Beschreibung | Status | Current Equivalent |
Xgard | Komplettes Sortiment an I.S.- und Exd-Detektoren für toxische, sauerstoffhaltige und brennbare Gase. | Aktuell | Aktuelles Produkt |
Xgard IR | Exd IR HC or CO2 Gas Detector | Aktuell | Aktuelles Produkt |
TXgard IS+ | I.S. Toxic/Oxygen Detector mit Display. | Aktuell | Aktuelles Produkt |
IRmax | IR-Gasdetektor aus Edelstahl | Aktuell | Aktuelles Produkt |
Xgard Bright | Vielseitiger Detektor mit Display | Aktuell | Aktuelles Produkt |
Xgard IQ | Stainless Steel Versatile Detector with Display with SIL2 | Aktuell | Aktuelles Produkt |
Smart 3G-D2 | Flammable, Oxygen, Toxic, VOC, and Refrigerationt gas Detector with Display for Zone 1 with SIL2 | Aktuell | Aktuelles Produkt |
Smart 3G-C2 | Flammable, Oxygen, Toxic, VOC, and Refrigerationt gas Detector for Zone 1 with SIL2 | Aktuell | Aktuelles Produkt |
Smart 3G-C3 | Flammable, Oxygen, Toxic, VOC, and Refrigerationt gas Detector for Zone 2 with SIL2 | Aktuell | Aktuelles Produkt |
Smart S-MS | Flammable, Oxygen, Toxic, VOC, and Refrigerationt gas Detector for Zone 1 with SIL2 | Aktuell | Aktuelles Produkt |
Smart S-MS MED | Flammable, Oxygen, Toxic, VOC, and Refrigerationt gas Detector for Zone 1 with SIL2 with Marine approval | Aktuell | Aktuelles Produkt |
Smart P | Addressable CO & NO2 gas detector for parking garage application | Aktuell | Aktuelles Produkt |
Smart 3-NC | Versatile low cost gas detector for Flammable & Toxic gases | Aktuell | Aktuelles Produkt |
Smart 3H-FM Lite | Low cost Refrigeration gas detector | Aktuell | Aktuelles Produkt |
TXgard Plus | Explosionsgeschützter Gift-/Sauerstoffgasdetektor mit Anzeige | Veraltet | Xgard Bright, Smart S or Smart 3G |
Flamgard Plus | Exd Explosionsgeschützter Detektor für brennbare Gase mit Anzeige | Veraltet | Xgard Bright, Smart S or Smart 3G |
RGD90 | Gift- und Sauerstoffgasdetektoren (eigensicher) | Nicht unterstützte | Xgard Type 1 |
RGD90/TC | Wärmeleitfähigkeits-Gasdetektor | Nicht unterstützte | Xgard Type 6 |
EXD90 | Explosionsgeschütztes Gasdetektor-Sortiment. Entflammbare, toxische, Sauerstoff-, Sulfistor- und TC-Versionen. | Nicht unterstützte | Xgard Types 2,3,5 & 6. |
TXgard-IS | Gift- und Sauerstoffgasdetektoren (eigensicher) | Nicht unterstützte | Xgard Type 1 |
TXgard-D | Explosionsgeschützter Toxiko-/Sauerstoffgasdetektor | Nicht unterstützte | Xgard Type 2 |
TXgard-HS | Exd Flameproof Sulphistor H2S Detector | Nicht unterstützte | Xgard Type 2 H2S. |
Flamgard Exe | Exe-Detektor für brennbare Gase | Nicht unterstützte | Xgard Type 3 |
Flamgard 4-20 | Explosionsgeschützter Detektor für brennbare Gase mit 4-20mA Ausgang. | Nicht unterstützte | Xgard Type 5 |
Flamgard HT | Hochtemperatur-Detektor für brennbare Gase | Nicht unterstützte | Xgard Type 4 |
Flamsafe | Non-certified flammable gas detector | Nicht unterstützte | Xgard Type 1 or Smart 3-NC |
TCgard | Wärmeleitfähigkeits-Gasdetektor | Nicht unterstützte | Xgard Type 1 or Xgard Bright |
Cirrus | IR HC or CO2 Gas Detector | Nicht unterstützte | IRmax, Xgard IR or Xgard IR CO2. |
Nimbus | IR HC-Gasdetektor | Nicht unterstützte | Irmax |
IREX | Pellistor-Ersatz-IR-Gasdetektor | Nicht unterstützte | Irmax or Xgard IQ |
Kellersafe | CO2 & O2 Detector with Display | Nicht unterstützte | Xgard, Xgard Bright, Smart 3-NC |
Sapphire | IR CO2 Detector with Display | Nicht unterstützte | Xgard IR CO2 |
Gaslink | Detektoren für giftige, sauerstoffhaltige und brennbare Gase mit Anzeige | Nicht unterstützte | TXgard-IS+ |
F-Gas-Detektor | Refrigerant gas and SF6 detector | Nicht unterstützte | Smart 3G-D2, Smart 3G-C2, Smart 3G-C3, Smart S-MS, Smart 3H-FM Lite |
Flammendetektoren |
|||
Modell | Beschreibung | Status | Current Equivalent |
Fgard IR3 | Multi-Spectrum IR Flame Detector | Aktuell | Aktuelles Produkt |
Fgard H2 | Multi-Spectrum IR Flame Detector Optimized for Hydrogen | Aktuell | Aktuelles Produkt |
Fgard UVIR | UV & Multi-Spectrum IR Flame Detector | Aktuell | Aktuelles Produkt |
Crowcon-Schalttafeln |
|||
Modell | Beschreibung | Status | Current Equivalent |
Gasmonitor | 1-16 Kanal 19″-Rack-Bedienfeld | Aktuell | Current rack-based control panel. Became Gasmonitor Plus in 1999. Full Tech Note history available. |
Vortex | 1-12-Kanal-Steuersystem für Wand-, Rack- oder Schaltschrankmontage. | Aktuell | Aktuelles Produkt |
Vortex FP | Exd Flameproof 1-12 channel control panel | Aktuell | Aktuelles Produkt |
Gasmaster (3rd Gen) | 1-4 channel wall mounted control panel. | Aktuell | Aktuelles Produkt |
Multiscan++ S2 | 1-256 Channel Enclosure or Rack Mounted Addressable Control System | Aktuell | Aktuelles Produkt |
Multiscan++ MED | 1-64 Channel Enclosure or Rack Mounted Addressable Control System with Marine Approval | Aktuell | Aktuelles Produkt |
Multiscan++ PK | 1-256 Channel Enclosure or Rack Mounted Addressable Control System for Parking Garage Applications | Aktuell | Aktuelles Produkt |
GM16 | Adressierbares 1-16-Kanal-Steuerungssystem im Gehäuse oder im Rack mit Fernzugriff | Aktuell | Aktuelles Produkt |
GM64 | 1-64-Kanal-Gehäuse oder Rack-montiertes adressierbares Steuerungssystem mit Fernzugriff | Aktuell | Aktuelles Produkt |
GM128 | 1-128-Kanal-Gehäuse oder Rack-montiertes adressierbares Steuerungssystem mit Fernzugriff | Aktuell | Aktuelles Produkt |
HMI | Touchscreen Controller Display Mimic für Vortex & Gasmaster Controller | Aktuell | Aktuelles Produkt |
Gaswarden 72GW/FP | 1-2 Kanal Exd-Bedienfeld | Nicht unterstützte | Vortex FP |
Gaswarden 85GW | 1-2 channel wall mounted controller | Nicht unterstützte | Gasmaster (3rd Generation) |
Gaswarde FP83GW/5 | 1-5 Kanal Exd-Bedienfeld | Nicht unterstützte | Vortex FP |
Gaswarden 83GW | 1-10 Kanal 19″-Rack-Bedienfeld | Nicht unterstützte | Gasmonitor or Vortex |
Gasmonitor 88GM | Überwachungssystem für Halon- oder CO2-Löschmittel. | Nicht unterstützte | Contact Crowcon |
Gasmaster 1 (1st Gen) | Einkanaliges wandmontiertes Bedienfeld | Nicht unterstützte | Gasmaster (3rd Generation) |
Gasmaster 4 (1st Gen) | 1-4-Kanal-Bedienfeld zur Wandmontage | Nicht unterstützte | Gasmaster (3rd Generation) |
Gasmaster FP (1st Gen) | Exd Flamneproof 1-4 channel control panel | Nicht unterstützte | Vortex FP |
Gasmaster (2nd Gen) | 1 oder 1-4 Kanal wandmontiertes Bedienfeld. | Nicht unterstützte | Gasmaster (3rd Generation) |
Gasflag | Einkanaliges wandmontiertes Bedienfeld | Nicht unterstützte | Gasmaster (3rd Generation) or PL4+ |
DI Modules & Control Panels |
|||
Modell | Beschreibung | Status | Current Equivalent |
DI 230 | Modul zur Erkennung brennbarer Gase | Nicht unterstützte | Vortex or GM controllers |
DI 280 | Modul zur Erkennung brennbarer Gase | Nicht unterstützte | Vortex or GM controllers |
DI 800 | Flammable gas detction module | Nicht unterstützte | Vortex or GM controllers |
DI 800 UN/mA | 4-20 mA Eingangsgasmodul (ersetzt DI-861/2) | Nicht unterstützte | Vortex or GM controllers |
DI 800 UN/mV | Millivolt-Eingangsgasmodul (ersetzt DI-800) | Nicht unterstützte | Vortex or GM controllers |
DI-810 | 4-20 mA Eingangsgasmodul (für DI 10 Detektor) | Nicht unterstützte | Vortex or GM controllers |
DI 860 | H2S-Gasmodul für Sulphistor-Detektoren. | Nicht unterstützte | Vortex or GM controllers |
DI 861/2 | Gasmodul 4-20 mA Eingang | Nicht unterstützte | Vortex or GM controllers |
DI 943B | Logik-Modul | Nicht unterstützte | Vortex or GM controllers |
DI 944 | Relaismodul | Nicht unterstützte | Vortex or GM controllers |
DI 947 | Löschsteuerungsmodul | Nicht unterstützte | Vortex or GM controllers |
DI 948 | Schlüsselschalter-Modul | Nicht unterstützte | Vortex or GM controllers |
DI 950 | Doppelzonen-Brandmelder-Modul | Nicht unterstützte | Vortex or GM controllers |
DI 951 | Leitungsüberwachungsmodul | Nicht unterstützte | Vortex or GM controllers |
DI 951 UN | Leitungsmonitor-Modul | Nicht unterstützte | Vortex or GM controllers |
DI 952 | Audio-Modul | Nicht unterstützte | Vortex or GM controllers |
DI 965 | Geschaltetes Programmlogikmodul | Nicht unterstützte | Vortex or GM controllers |
DI 970 | Selbsttestmodul (Gas) | Nicht unterstützte | Nicht gleichwertig. Kontaktieren Sie Crowcon für technische Lösungen |
DI 978 | Wechselrichter-Modul | Nicht unterstützte | Nicht gleichwertig. Kontaktieren Sie Crowcon für technische Lösungen |
DI-980 | Diodenmatrix-Modul | Nicht unterstützte | Nicht gleichwertig. Kontaktieren Sie Crowcon für technische Lösungen |
DI-11 System | 16-Kanal 19″ Rack-basiertes Detektionssystem für brennbare Stoffe und H2S. Merkmale DI 1-11, 2-11, 4-11 Module. | Nicht unterstützte | Vortex or GM controllers |
SP-11 | Wandmontierte Einkanal-Steuertafel für brennbare Gase | Nicht unterstützte | Gasmaster or PL4+ |
DI-4000 | Wandmontierte 1-4-Kanal-Steuertafel für brennbare Gase | Nicht unterstützte | Gasmaster |
Muster-Systeme |
|||
Modell | Beschreibung | Status | Current Equivalent |
PGS32 | Programmable sampling system. Control module has Parallel PC connection and is Windows 98 compatible only. | Nicht unterstützte | Kontaktieren Sie das EFS-Team für Optionen |
PGSi | Programmable sampling system. Control module has Parallel PC connection and is Windows XP/Vista compatible only. | Nicht unterstützte | Kontaktieren Sie das EFS-Team für Optionen |
MillGard | Coal-mill CO sampling system. | Nicht unterstützte | Kontaktieren Sie das EFS-Team für Optionen |
Zubehör |
|||
Modell | Beschreibung | Status | Current Equivalent |
Xgard ESU | Probenahmegerät für schwere Gase/Dämpfe | Aktuell | Aktuelles Produkt |
Xgard ASU | Kanalprobenahmegerät für Xgard | Aktuell | Current model for Xgard (except Xgard Type 4). |
87ESU | Probenahmegerät für schwere Gase/Dämpfe | Nicht unterstützte | Xgard ESU; Gasmaster will also need updating to new Gasmaster. |
86ASU | Kanalprobenahmegerät für RGD90, TXgard-IS oder Flamgard Exe | Nicht unterstützte | Xgard ASU; Gasmaster will also need updating to new Gasmaster. |
Feuertafeln |
|||
Modell | Beschreibung | Status | Current Equivalent |
Brandmeister | Konventionelle Brandmeldezentrale mit 1-12 Zonen | Nicht unterstützte | Keine |
(List updated 11th April 2024)