In the global food and beverage industry, safety and hygiene are the foundation of operational success. Beyond maintaining product quality, facilities must manage a complex array of invisible atmospheric hazards that are inherent to fermentation, carbonation, and industrial refrigeration.
This guide serves as a technical blueprint for site managers and safety engineers. It details how to identify specific gas risks and implement a layered safety strategy using Crowcon’s solutions. By aligning precision hardware with digital oversight, facilities can protect their personnel and infrastructure while maintaining maximum uptime.
In this article, you will learn:
- Identification of high-risk gases: From fermentation byproducts to toxic refrigerants.
- Strategic equipment mapping: Selecting fixed and portable solutions for specific operational zones.
- Digital compliance: Using connected safety to automate exposure logging and maintenance.
By the end of this article, you’ll be able to understand how Crowcon’s range of products can help you.
Primary Atmospheric Hazards in Production Environments
The very processes that produce food and beverage products also generate life-threatening concentrations of gas. Effective detection requires understanding the physical properties of these gases and where they are likely to accumulate.
Carbon Dioxide (CO2): The Silent Asphyxiant
Carbon dioxide is a natural byproduct of yeast fermentation and is used extensively for carbonation and as dry ice for transportation. Because CO2 is five times heavier than air, it does not dissipate easily; instead, it settles in low-lying areas like pits, sump areas, and bottling halls.
Standard atmospheric CO2 is approximately 400 ppm, but concentrations as low as 7% can cause death in only five minutes. Because CO2 is colourless and odourless, it cannot be detected by human senses, making dedicated infrared (IR) sensors a technical necessity for 24/7 area monitoring.
Ammonia (NH3): The Dual Threat
Ammonia remains the refrigerant of choice for large-scale cold storage due to its exceptional cooling efficiency. However, it is both highly toxic and flammable at concentrations of 15% (LEL).
NH3 is lighter than air and fills enclosed plant rooms rapidly in the event of a flange or seal failure. Its corrosive nature means it can burn the respiratory tract upon inhalation. Crowcon utilises electrochemical sensors for toxic-level detection (ppm) and catalytic sensors for flammability monitoring, ensuring a comprehensive safety net around refrigeration infrastructure.
Nitrogen (N2) and the Risk of Oxygen Depletion
Modified Atmosphere Packaging (MAP) uses Nitrogen to displace oxygen and prevent food spoilage. While Nitrogen is inert, any leak in a confined packaging area can rapidly reduce breathable oxygen levels.
Safety protocols must focus on maintaining oxygen levels within the recognised safe range of 19.5% to 23.5%. Normal atmospheric oxygen is approximately 20.9% by volume. When oxygen levels fall below 19.5%, personnel may experience impaired judgement, dizziness and fatigue, while further reductions can quickly lead to loss of consciousness and other life-threatening consequences. Continuous monitoring with portable detectors is the only reliable way to verify that a packaging zone remains safe for entry.
Targeted Safety in Alcohol Manufacture
Breweries and distilleries face unique volatility risks, particularly regarding ethanol vapours and combustible dust generated during grain processing.
Ethanol Vapour (C2H5OH) and Flammability
In distilleries, ethanol vapours are emitted from transfer pumps, pipes, and aging casks. These vapours are highly flammable and pose a persistent explosion risk.
Why Xgard Bright with MPS™ works best here: Traditional pellistor sensors are often “poisoned” by the silicone-based cleaning agents used in food-grade environments, leading to sensor failure without warning. Crowcon’s Xgard Bright with Molecular Property Spectrometer (MPS™) technology is immune to poisoning.
It is the superior choice for distilleries because it provides “TrueLEL™” accuracy for ethanol and 15+ other flammable gases simultaneously, ensuring the system never fails to alarm when it matters most.
Product Details: https://www.crowcon.com/products/xgard-bright/
Managing Combustible Dust and Ignition
The first stage of brewing and distilling involves handling, storage, and milling of malt grains. This creates fine dust that is highly explosive if extraction systems fail. Facilities must integrate flame detection alongside gas monitoring to provide an instant response to ignition events.
Confined Space Entry (CSE) Protocols
Cleaning vats and fermenters requires technicians to enter confined environments where CO2 levels are likely to be elevated.
Why Gas-Pro works best for Pre-Entry: Entering a fermentation vessel is a high-stakes task where the atmosphere at the bottom may be radically different from the top.
The Gas-Pro is the optimal choice for this situation because of its internal pump and unique Pre-Entry Check (PEC) mode. This allows an operative to drop a sampling line up to 30 metres into the tank, verifying safety from the outside before a human ever enters. Its top-mount display also allows for hands-free monitoring while the worker is inside the vessel.
Product Details: https://www.crowcon.com/products/gas-pro/
Engineering Safety into Processing and Logistics
Secondary processing halls and logistics hubs introduce chemical hazards through disinfection protocols and the use of industrial steam boilers.
Boiler Room and Combustion Monitoring
Industrial boilers powered by Methane (CH₄) or LPG (Propane) are common throughout food processing facilities. Incomplete combustion in these enclosed spaces can lead to a build-up of Carbon Monoxide (CO), often referred to as the “silent killer”.
When responding to boiler faults, carrying out maintenance, or working in plant rooms, facility engineers can be exposed to hazardous CO levels without any visible warning signs. Wearing a personal CO monitor provides continuous protection, alerting workers immediately if concentrations begin to rise so they can take action before conditions become dangerous. Single-gas devices such as UnoIQ offer a simple, reliable solution for monitoring CO exposure during routine inspections and maintenance activities.
Product Details: https://www.crowcon.com/products/unoiq
Disinfection and Wash-down Hazards
Rigorous hygiene standards require the use of Chlorine (Cl2) or Ozone (O3) for surface sterilisation. These chemicals are highly reactive and corrosive. Exposure to even low levels of Chlorine can cause severe respiratory distress.
Why XgardIQ works best in Wash-down Zones: Food production halls are subject to frequent high-pressure wash-downs. The XgardIQ is the preferred solution here because of its 316 stainless steel housing, which provides maximum corrosion resistance.
Its “hot-swappable” sensor modules allow for maintenance without opening the flameproof enclosure or requiring a hot-work permit—keeping production lines running even during safety checks.
Product Details: https://www.crowcon.com/products/xgardiq/
H2: Industrial Refrigeration Safety: Protecting the Cooling Chain
Industrial cooling systems rely on high concentrations of refrigerants that pose significant toxicity and flammability risks. Large-scale facilities use ammonia or CO2, while commercial HVAC-R units increasingly utilise A2L refrigerants which are mildly flammable. Continuous monitoring around compressors, valves, and evaporators prevents gas loss and ensures regulatory compliance.
The SMART 3G Series provides specialized detection for over 50 specific refrigerant gases, including F-gases and natural refrigerants like R290. For machine rooms with extreme temperature shifts, the SMART 3G-D2 operates reliably from -40°C to +50°C. These fixed units integrate with ventilation controls to trigger automated cooling or shutdown if a leak is identified.
Personal Protection: Portable Safety Solutions
Crowcon’s portable range is designed for durability and ease of use, ensuring that every worker carries a reliable shield against atmospheric hazards.
UnoIQ & DuoIQ: The Modular Advantage
Why the IQ Range works best for Shifting Risks: In many F&B facilities, the gas risk changes by the hour. A worker might be in a cold store (Ammonia) in the morning and a packaging line (Nitrogen/CO2) in the afternoon. The UnoIQ and DuoIQ work best in these variable circumstances because of their modular sensor trays.
Instead of carrying multiple bulky devices, a worker can simply swap a pre-calibrated sensor tray in the field to match the specific hazard of their current task. With long-lasting battery life, it is the lowest-maintenance personal monitor available.
UnoIQ Details: https://www.crowcon.com/products/unoiq/
DuoIQ Details: https://www.crowcon.com/products/duoiq/
T4 & T4x: High Performance, Low Ownership Cost
Why T4x works best for standard 4-gas protection: For workers who spend their entire 12-hour shift in areas with potential LEL, O2, CO, and H2S risks, the T4x is the industry standard. It works best for long-duration shifts because of its 35+ hour battery life.
Its “TWA Resume” function is critical for compliance, as it retains exposure data even if the device is switched off during a break, ensuring that the worker’s cumulative exposure for the day is accurately recorded.
Product Details: https://www.crowcon.com/products/t4/
Fixed Systems: Continuous 24/7 Sentinels
Fixed detection systems provide a permanent safety infrastructure, offering continuous monitoring that portable devices cannot replicate.
SMART 3G Series: Specialised Refrigerant Detection
Why SMART 3G works best for Machine Rooms: HVAC-R systems in food processing often utilise A2L refrigerants, which are mildly flammable and require precise monitoring.
The Sensitron SMART 3G range works best in machine rooms because it is pre-configured for over 50 specific gases, including F-gases and natural refrigerants like R290. Its non-intrusive calibration allows site staff to calibrate the unit via a magnetic pen without declassifying the area, significantly reducing operational downtime.
Product Details: https://www.crowcon.com/products/smart-3g-d2/
Centralised Command: Vortex & Gasmaster
A fixed system is only as effective as its control hub.
Gasmaster: Works best for smaller, single-room applications (e.g., a chlorine dosing room) where a simple, wall-mounted display of up to four channels is needed.
Vortex: Works best for larger processing areas where up to 12 detectors must be integrated into a wider PLC or SCADA system via Modbus RTU, providing flexible control and monitoring across multiple zones.
Multiscan++S2: Works best for more complex installations requiring centralised control of larger detector networks. Supporting up to 256 addressable devices, it provides advanced alarm management, event logging, and seamless integration with plant control systems, making it ideal for extensive food and beverage facilities with multiple monitoring points and varied gas hazards.
Gasmaster Details: https://www.crowcon.com/products/gasmaster/
Vortex Details: https://www.crowcon.com/products/vortex/
Multiscan++S2 Details: https://www.crowcon.com/products/multiscans2/
Conclusion
Gas safety in the food and beverage industry requires a tailored, multi-layered approach. By integrating fixed area monitoring with intelligent portable protection, operators can maintain the highest safety standards while ensuring their facility remains efficient and compliant.
The combination of precision engineering—such as Crowcon’s XgardIQ and MPS™ technology—with the digital oversight of Crowcon Connect represents a new era in industrial safety: one that is data-driven, transparent, and uncompromising.
For further information read our case study below.
- Brewery CO2 Monitoring Case Study: Crowcon designs and installs CO2 monitoring for a large brewery in a listed building – Crowcon Detection Instruments Limited
Subscribe to get the latest insights
IN your box
Read about Crowcon’s Privacy and Cookie policy here. If you change your mind, you can unsubscribe at any time