Specifications
Size |
90 x 48 x 24 mm (3.5 x 1.9 x 0.95 ins) |
Weight |
Flammable: 138g (4.9oz)
Toxic: 85g (3oz)
Oxygen: 129g (4.6oz)
Carbon monoxide: 139g (4.9oz) |
Typical response times (T90) |
Flammable: 20s
Flammable (MPS): 17s
Toxic gas: 20s
Oxygen: 10s
Oxygen (Long-Life): 10s |
Alarms |
Audible: 95dB; Multiple alarm options let you select distinctive tones for different alarm levels
Visible: Dual colours red/ blue flashing LEDs in a gas hazard
Internal vibrating alarm |
Display |
Custom LCD with backlight, with display of gas concentration. Graphic symbols for battery (with proportional indication of remaining operation time), and display mode. Start up indication when calibration is due within 30 days, calibration overdue or service required.
Normal display: Real time gas concentration levels
Display recall: Peak readings and TWA |
Data logging |
Full timed datalogging with adjustable sample rate, set to 1 min. data rate as default.
900 hours storage at 1 min. interval (54,000 logs), >4800 events |
Battery |
Rechargeable lithium battery for all gas types
Non-rechargeable lithium battery for toxics and oxygen (excluding CO2) |
Operating time* |
Rechargeable with MPS: >3days
Rechargeable: 12 hours minimum for flammable unit
Non-rechargeable: Up to 2 years |
Sampling |
Optional manual aspirator |
Operating temperature** |
-20°C to +65°C (-4°F to +149°F) |
Humidity |
5 – 95% RH
0 to 99% RH (O2 LL MPS) |
Ingress protection |
IP65 |
Approvals |
Europe: Toxic or O2: ATEX II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0384
Flammable: ATEX II 2G Ex ia db IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0383Flammable (MPS): ATEX II 1G Ex ia IIC T4 Ga (-20°C ≥Ta ≥ +65°C) BASEEFA04ATEX0383
International: Toxic or O2: IECEx Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BAS05.0039
Flammable: IECEx Ex db ia IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BAS05.0038
North America: CSA Class 1 Groups A,B,C,D Division 1 |
Standards |
Europe: EN60079-0, EN60079-11, EN60079-1, ATEX 2014/34/EU
North America: CSA22.2, 152EN50270, EN50271, EN61779 |
PC Interface |
RS232 connection from interface module in charger
RS232/USB converter available |
Calibration |
Gasman can be routinely calibrated using Portables PC software or by using Checkbox IMH |
Accessories |
Gasman is supplied with an integral alligator clip.
Optional accessories:
Gas test kit, Gasman external filter, leather carry case, single way charger, charger interface software and communication kit (excluding PSU), 5 way multi-charger |
Crowcon Connect Compatible? |
Yes |
*Operating time will depend on operating pattern and alarm occurrence. Frequent or long lasting alarms and use of the optional confidence beep will reduce battery life.
**Toxic and oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40°C (104°F) for extended periods.
Gases and Ranges
Required ranges and alarms vary by country and application and these can be configured as required. Each gas channel can have two instantaneous alarm levels set. Toxic units also have Time Weighted Average (TWA) alarms.
Flammable gas calibration is available for methane, propane, butane, pentane, hydrogen and
ethylene as standard.
Gasman is also available in a safe area CO2 version offering 0-5% carbon dioxide measurement.
Gas |
Range |
Standard Alarm (UK) |
Ammonia (NH3) |
0-1000 ppm |
25 ppm |
Carbon Monoxide (CO) |
0-1500 ppm |
20 ppm |
Carbon Dioxide (CO2) |
0-5% vol. |
0.5% vol. |
Carbon Monoxide (H2
filtered) |
0-500ppm |
20ppm |
Chlorine (Cl2) |
0-20 ppm |
0.3 ppm |
Chlorine Dioxide (CIO2) |
0-1 ppm |
0.1 ppm |
Ethylene Oxide (ETO) |
0-10 ppm |
3 ppm |
Flammable True LEL (MPS) |
0-100% LEL |
20% LEL |
Flammable |
0 – 100% LEL |
20% LEL |
Fluorine (F2) |
0-1 ppm |
0.5 ppm |
Hydrogen (H2) |
0-2000 ppm |
N/A |
Hydrogen Cyanide (HCN) |
0-25 ppm |
5 ppm |
Hydrogen Fluoride (HF) |
0-10 ppm |
1 ppm |
Hydrogen Sulphide (H2S) |
0-250ppm |
5 ppm |
Nitric Oxide (NO) |
0-100 ppm |
25 ppm |
Nitrogen Dioxide (NO2) |
0-20 ppm |
1 ppm |
Oxygen (O2), Long-Life |
0-25% vol. |
19.5% / 23.5% vol. |
Oxygen (O2) |
0-25% vol. |
19.5% / 23.5% vol. |
Ozone (O3) |
0-1 ppm |
0.1 ppm |
Phosphine (PH3) |
0-5 ppm |
0.1 ppm |
Phosgene (COCL2) |
0-1 ppm |
0.1 ppm |
Sulphur Dioxide (SO2) |
0-20 ppm |
1 ppm |