XGARD BRIGHT
Available with MPS™ technology to eliminate risk of poisoning and need for calibration, the Xgard Bright is the next generation of multi-gas detection. This fixed detector offers flammable and toxic gas detection and oxygen monitoring, combined with reduced installation costs and ease of operation.
Where to Buy











Xgard Bright is a versatile detector offering flammable and toxic gas detection and oxygen monitoring, while providing ease of operation and reduced installation costs.
Choose from durable sensor options to suit your needs, such as MPSTM (10+ years), Long-life O2 (5 years) and IR sensors (10+ years) to prevent frequent sensor replacements and minimise operational expenses.
Lowering the cost of installation, the 4-wire addressable implementation drastically reduces cabling requirements. The large OLED display allows users to easily work with Xgard Bright during install, calibration and routine maintenance without the need to open the housing.
Providing analogue 4-20mA and RS-485 Modbus signals as standard, Xgard Bright comes with an Alarm and Fault relay as standard as well as optional HART communications.


MPS™ sensor available
Low installation cost
Easy operation
4-20mA and RS-485 Modbus signals
Alarm and Fault relay
Next Generation Sensor Technology
- MPS™ (Molecular Property Spectrometer) technology
- TrueLEL™ multi-gas accuracy
- Free from risk of sensor poisoning
- No calibration or scheduled maintenance is needed
-
Hydrogen ready

Versatile
- Available in both high-grade aluminium alloy or 316 stainless steel
- Flammable and toxic gas detection, as well as oxygen monitoring options
- Choose from MPS™, Long-Life O2 and IR sensor options, all with long lifespans
- Choice of M20 or ½”NPT connection to suit your specific site requirements
- Low power usages (~3W max) helping reduce site-wide power consumption
- IP65 or IP66 rating (with weatherproof cap), allowing for use in areas subject to regular wash downs or in exposed environments

Ease of Installation & Operation
- Addressable operation reduces the amount of cabling needed for multi-point installations
- Local display delivers gas level indication and device status at a glance
- Non-intrusive calibration eradicates the need to open the cover for calibration
- Plug in type terminal blocks for reduced installation costs
- Configuration via magnetic key helps minimise the amount of time operators spend in a hazardous area

| Size |
Aluminium enclosure: ATEX/IECEx: 156 x 166 x 109 mm (6.1 x 6.5 x 4.3 inch) UL: 162 x 166 x 110 mm (6.4 x 6.5 x 4.3 inch) Stainless Steel Enclosure: ATEX/IECEx: 165 x 166 x 105 mm (6.1 x 6.5 x 4.1 inch) UL: 162 x 166 x 103 mm (6.4 x 6.5 x 4.1 inch) |
| Cable Gland Entry | 2x M20 or 2x ½” NPT (Stopping plug fitted to the left-side entry) |
| Operating Voltage | 12-30Vdc. |
| Power | 3W max |
| Electrical Output | 3-wire 4-20mA (Sink or Source) RS-485 Modbus RTU HART 7 (Optional) |
| Weight |
Aluminium enclosure: ATEX/IECEx: 1kg (2.2 lbs) UL: 1.5 kg (3.31 lbs) Stainless Steel Enclosure: ATEX/IECEx: 3.1 kg (6.8 lbs) UL: 3.5 kg (7.72 lbs) |
| Enclosure Material | ADC 12 aluminium alloy or 316 stainless steel |
| Relay | Alarm 1, Alarm 2, Fault (SPDT Contacts. Rated 1A, 24Vdc) |
| Sounder Out | High Side Switch (24V nominal, 12V minimum, 700mA maximum load) |
| Operating Temperature |
ATEX/IECEx: -40°C to +70°C (-40°F to 158°F) UL: -40°C to +60°C (-40°F to 140°F) |
| Humidity |
0 to 95% RH, non-condensing Contact Crowcon for sensor operating humidity range. |
| Repeatability | +/- 2% FSD |
| Zero drift | +/- 2% FSD per year maximum |
| Ingress protection | IP65/66, EN 60529 |
| Hazloc Standards & Approvals |
ATEX: EN IEC 60079-0, EN 60079-1, EN 60079-31 IECEx: IEC 60079-0, IEC 60079-1, IEC 60079-31 Zone 1 and Zone 2 or Zone 21 and Zone 22 Aluminium: Ex II 2 G Ex db IIC T6 Gb Tamb: -40°C≤Ta≤70 °C Ex II 2 D Ex tb IIIC T80°C Db Ex db IIC T6 Gb Tamb: -40°C≤Ta≤70 °C Ex tb IIIC T80°C Db Stainless Steel: Ex II 2 G Ex db IIC T3 Gb Tamb: -40°C≤Ta≤70 °C Ex II 2 G Ex db IIC T4 Gb Tamb: -40°C≤Ta≤50°C Ex II 2 D Ex tb IIIC T80°C Db Ex db IIC T3 Gb Tamb: -40°C≤Ta≤70°C Ex db IIC T4 Gb Tamb: -40°C≤Ta≤50°C Ex tb IIIC T80°C Db UL: UL 1203 -40°C≤Ta≤60 °C Class I, Division 1, Groups B, C, D T6 Class II Division 1, Groups E, F, G T6 |
| Approvals |
UL, IECEx, ATEX, CE, INMETRO, ECAS, PESO, CNEx, UC, CCSA TA, MED |
| EMC Compliance | EN 50270, EN IEC 61326-1, EN 55011, CISPR 11, EN 61000-4 |
| Zones | Certified for use in Zone 1 and Zone 2 areas |
| Warranty |
2 years on transmitter 5 years on MPS flammable and O2 Long Life sensor 2 years on IR flammable sensors Refer to GEN067 – Warranty Periods for other sensors |
| Gas | Sensor type | Gas range | Temp range °C |
| Flammable gases (Tested for Methane, Butane, Ethane, Ethylene, Hydrogen, LPG, Pentane, Propane) | MPS | 0-100% LEL | -40 to +75 |
| Butane (C4H10) | Infrared | 0-100% LEL | -40 to +60 |
| Hydrogen (H2) | Catalytic | 0-100% LEL | -40 to +70 |
| LPG |
Catalytic Infrared |
0-100% LEL |
-40 to +70 -40 to +60 |
| Methane (CH4) |
Catalytic Infrared |
0-100% LEL 0-100% LEL |
-40 to +70 -40 to +60 |
| Pentane (C5H12) |
Catalytic Infrared |
0-100% LEL 0-100% LEL |
-40 to +70 -40 to +60 |
| Propane (C3H8) |
Catalytic Infrared*** |
0-100% LEL 0-100% LEL |
-40 to +70 -40 to +60 |
| Carbon Monoxide (CO) | Electrochemical | 0-25, 50, 100, 200, 250, 300, 1000, 2000 ppm | -30 to +50 |
| Hydrogen Sulphide (H2S) | Electrochemical | 25, 50, 100, 200 ppm | -40 to +50 |
| Oxygen (O2) Long Life (Lead free) | Electrochemical | 0-25% vol | -40 to +60 |
| Oxygen (O2) | Electrochemical | 0-25% vol | -20 to +50 |
| Carbon Dioxide (CO2) | Infrared | 0-5% vol | -40 to +60 |
|
* Contact Crowcon for more information |
|||
| Gas | Sensor type | Gas range | Temp range °C |
| Flammable gases* | MPS | 0-100% LEL | -40 to +75 |
| Ammonia (NH3) | Electrochemical | 0-50, 100 ppm | -40 to +50 |
| Chlorine (CL2) | Electrochemical | 0-5, 10 ppm | -20 to +50 |
| Hydrogen Cyanide (HCN) |
Electrochemical |
0-25 ppm |
-40 to +40 |
| Hydrogen Peroxide (H2O2) |
Electrochemical |
0-5 ppm |
-20 to +50 |
| Sulphur Dioxide (SO2) |
Electrochemical |
0-10 ppm |
-20 to +50 |
| VOC* | PID | 0-1000 ppm | -20 to +60 |
| Ozone (O3) | Electrochemical | 0-1 ppm | -20 to +40 |
| Carbon Dioxide (CO2) | Infrared | 0-5% vol | -40 to +60 |
| * Contact Crowcon for more information |
|||
accessories

Collector Cone C01051
Aids detection of lighter than air gases such as hydrogen or methane. Includes a pipe spigot for application of bump…

Spray deflector C01052
For outdoor installations and sensor protection from water sprays.

Weatherproof cap C01442
For use offshore or very wet environments

Flow adaptor C01339
For use in sampling applications

Sun shield C011063
Prevents against excessive heat build-up due to direct sunlight.

Calibration adaptor C03005
Enables application of calibration gas to the sensor.